The AWS-4000 is a versatile data collection system that allows the user to track multiple tools and their associated torque readings. Individual tools can be assigned an alphanumeric serial number, and each serial number can be assigned to an associated group. The AWS-4000 can be used in automatic (routing) or manual (individual entry) mode.

Utilizing Intellect technology, "smart" transducer calibration data is automatically accessed. This provides independent calibration and interchangeability. The auto-recognition feature ensures correct transducer selection without user intervention.

    Up to 500 serial numbers, 64 groups, 8000 total readings may be stored in the unit at one time. A maximum of 1000 readings may be stored for one serial number. LEDs on front panel indicate pass/fail readings.

    As each reading is entered into memory it will also be sent out the serial port along with a date/ time stamp. A failure indicator will follow any readings that are outside of the given limits.

    The AWS4000 can be used in Serial Number or Route Mode. In Serial Number Mode, the operator inputs the alphanumeric serial number assigned to the tool being tested. Route Mode enables operators to quickly select serial numbers. Torque readings compared to high/low limits provide Cp/Cpk information.

SPECS:

  • Width: 4 "
  • Height: 2.25 "
  • Depth: 8 "
  • Operating Temp: 10-50°C
  • Battery Type: NiMH
  • Line Input Power: 12 VDC (mains adapter provided)

FEATURES:

  • Bidirectional accuracy of ±0.5% of indicated reading with AWS transducers, ±1% of indicated reading with rotary transducers.
  • Eight (8) available engineering units:
  • Oz.in., Lb.in., Lb.ft., Nm, cNm, KgfCm, gfCm, Kgfm.
  • 3 modes of operation: Track, Peak and 1st Peak with visual limit alarms.
  • Memory storage for 8000 data points.
  • RS-232 output.
  • NiMH rechargeable batteries provide 8-10 hours continuous use.
  • Selectable power tool filtering speeds: 125Hz, 250Hz, 500Hz, 1000Hz, 1500Hz and 2000Hz.
  • Can be calibrated to virtually any manufacturer’s strain gauge transducers.
  • Date and Time.
  • Alphanumeric Serial Number Input.
  • Serial Number association by Group.

Do you have a question or need application assistance?